Merge pull request #111692 from lopsided98/chrony-initstepslew-types

nixos/chrony: split the initstepslew attrset into options
This commit is contained in:
Martin Weinelt 2021-08-08 15:03:06 +02:00 committed by GitHub
commit 611bc7c23b
No known key found for this signature in database
GPG key ID: 4AEE18F83AFDEB23

View file

@ -81,17 +81,26 @@ in
'';
};
initstepslew = mkOption {
type = types.attrsOf (types.either types.bool types.int);
default = {
enabled = true;
threshold = 1000; # by default, same threshold as 'ntpd -g' (1000s)
initstepslew = {
enabled = mkOption {
type = types.bool;
default = true;
description = ''
Allow chronyd to make a rapid measurement of the system clock error
at boot time, and to correct the system clock by stepping before
normal operation begins.
'';
};
threshold = mkOption {
type = types.either types.float types.int;
default = 1000; # by default, same threshold as 'ntpd -g' (1000s)
description = ''
The threshold of system clock error (in seconds) above which the
clock will be stepped. If the correction required is less than the
threshold, a slew is used instead.
'';
};
description = ''
Allow chronyd to make a rapid measurement of the system clock error at
boot time, and to correct the system clock by stepping before normal
operation begins.
'';
};
directory = mkOption {